Controller Q200
Characteristics
Tank filling automation
Operation with direct current (DC) and alternating current (AC)
Electronic or mechanical float switch
Controller Technical Data Q200
The SP Monitor is a microcontroller, designed, developed and manufactured for the SOLAR pump.
• It is suitable for simultaneous AC and DC power.
• Manual or automatic switching between two power sources depending on solar irradiation.
• IP65 weather resistant housing.
• Suitable for pumps up to 2.2 kW (3 CV).
• Voltage input range AC 1X90 – 240 VAC. Terminals L N y GND
• DC voltage input range 60 – 380 Vmp/440VOC. Terminals + – and GND
• Input connections for 1 or 2 float switches. TWL Y WWL
• Input connection for the pressure switch. TWL
• Input connection for the corresponding flowmeter. FLOW SIGNAL -> REF. Flowmeter function setting (on this page)
• Indication of power on, input power, pump on, pump off, water tank full or tank empty.
• Automatic operation by means of 1 or 2 float switches.
• Automatic operation by pressure switch.
• Automatic shutdown by flowmeter.
• Automatic start of the generator by free voltage contacts. GENE SIGNAL
• Manual operation.
• Automatic switching of AC to DC power with DC bias. The DC switching point is 40 V.